Process

US heating section in the plastic recycling process

Ukraine
  • Year: 2014
  • Series: US
  • Total Power: 600 kW
Request
  • Recycling process of plastic bags.
  • Production of overheated and clean air at +140°C.
  • Working with gas, no steam, no electric heating.
Plant solution
  • 2 condensing heating sections US series.
  • High efficiency heat exchanger in counterflow with 4 smoke rounds.
  • Temperature deviation 130 K.
  • Modulating burner with active temperature probe 4-20mA.
  • Reinforced insulation casing.
  • Units can be interfaced with the process supervision system.
Advantages
  • More simple and cheaper solution compared with the alternative steam system.
  • Lower energy costs compared with the alternative electric heating system.
  • High thermal efficiency > 94%.