Keypoints

  • Designed for outdoor installation without additional protections
  • Maximum energy efficiency and environmental comfort thanks to power modulation and condensation operation at reduced thermal load
  • Heat exchanger made entirely of stainless steel AISI 304 with aerodynamic profile and turbulent imprints
  • High efficiency ~ 103%
  • Can be combined with gas or diesel blown air burners, with two-stage or modulating operation
  • 8 models with thermal capacity from 20 kW to 1.100 kW and air flow from 4.600 to 71.000 m3/h
  • Suitable for ducted or direct diffusion systems with air outlet plenum
read more

Warm Air Heaters

ENERGY/K Condensing vertical warm air heaters for outside installation

Type
Hot
Supply
Gas
Oil
Thermal
power
from 23,0
to 1.090,0
Air flow
from 4.600
to 71.000

Tecnoclima condensing vertical space heaters for outside installation ENERGY/K are the ideal solution for heating and controlled ventilation of medium large areas such as workshops, laboratories, industrial halls, warehouses, gyms, shopping centers, exhibition halls, theaters, churches, etc.

read more

Product informations

Description

External casing in pre-painted or powder-coated galvanized steel with insulation.

Heat exchanger three smokes rounds, with combustion chamber made of AISI 430 stainless steel, smoke pipes in AISI 304 stainless steel including turbolators, exhaust manifold with condensate discharge, inspection doors, chimney connection and burner mounting plate with insulation.

Fan section with one or more high performance centrifugal fans, complete with electric motor and variable belt transmission.

Electrical board for control and protection of the warm air heater designed for three phase electrical motor supply 400V 50Hz 3N, complete with FAN-LIMIT double thermostat (n°1 with manual reset and n°1 with automatic reset).

Technical features

Description

U.M.

ENERGY 60/K

ENERGY 105/K

ENERGY 160/K

ENERGY 220/K

Max nominal heating capacity input (burned)

kW

68,2

115,1

175,7

246,1

kcal/h

58.650

98.986

151.105

211.650

Max USEFUL heating capacity output

kW

60,1

103,5

160,3

217,1

kcal/h

51.686

89.010

137.858

186.706

Nominal air flow

Nm3/h

4.600

8.000

11.000

15.000

Useful static pressure

Pa

220

220

220

220

 

Description

U.M.

ENERGY 320/K

ENERGY 460/K

ENERGY 640/K

ENERGY 970/K

Max nominal heating capacity input (burned)

kW

349,8

502,9

715,2

1.089,8

kcal/h

300.830

432.495

615.045

937.230

Max USEFUL heating capacity output

kW

323,9

465,2

648,6

970,0

kcal/h

278.554

400.072

557.796

834.200

Nominal air flow

Nm3/h

21.500

31.000

43.000

71.000

Useful static pressure

Pa

220

220

220

220

Dimensions

Model

Dimensions mm

Chimney Ø mm

Weight kg

Weight (with package) kg

A

B

C

C1

D

E

ENERGY 60/K

812

540

1.700

-

600

100

150

180

185

ENERGY 105/K

1.060

760

2.046

-

600

100

200

310

315

ENERGY 160/K

1.300

900

2.240

-

600

100

250

500

507

ENERGY 220/K

1.500

1.000

2.240

-

800

100

250

610

617

ENERGY 320/K

1.700

1.200

2.470

-

800

100

300

850

857

ENERGY 460/K

2.090

1.270

1.180

1.870

1.000

170

300

1.310

1.320

ENERGY 640/K

2.500

1.500

1.180

2.120

1.000

170

350

1.800

1.810

ENERGY 970/K

3.500

1.500

1.380

2.120

1.000

170

400

2.500

2.510

Supply description

CONDENSING WARM AIR HEATER consisting of:

  • Heat exchanger three smokes rounds, with combustion chamber made of AISI 430 stainless steel, smoke pipes in AISI 304 stainless steel including turbolators, exhaust manifold with condensate discharge, inspection doors, chimney connection and burner mounting plate with insulation.
  • External casing in pre-painted or powder-coated galvanized steel with insulation.
  • Side panel for air inlet section.
  • Burner and electrical board protection box with inspection door and air ventilation grid.
  • Galvanized steel support frame.
  • Fan section with one or more high performance centrifugal fans, complete with electric motor and variable belt transmission.
  • Electrical board for control and protection of the warm air heater designed for three phase electrical motor supply 400V 50Hz 3N, complete with FAN-LIMIT double thermostat (n° 1 with manual reset and n° 1 with automatic reset).


PACKAGE: Warm air heaters are wrapped in plastic film.

Accessories

ENERGY/K - Tecnoclima spa

  1. Antirain inlet protection

  2. Air filter

Antirain inlet protection - Tecnoclima spa

1. Antirain inlet protection for air inlet mounting, complete with safety grid.

Air filter - Tecnoclima spa

2. Air filter complete with metallic cabinet, with replaceable and regenerable filter elements, safety pressure switch for burner stopping when filter elements are obstructed (excluded for ENERGY/K 60 and ENERGY/K 105 models).

Regulation damper - Tecnoclima spa

Regulation damper made of galvanized steel, with opposed closing/opening blades and actuator pin. Power supply singlephase 230V 50Hz 1N.

Manual control - Tecnoclima spa

Manual control with different positions for air inlet damper.

Damper proportional actuator - Tecnoclima spa

Damper proportional actuator degree IP 54, for the damper regulation.

Remote control - Tecnoclima spa

Remote control for the remote damper command with 0 ÷ 10V output.

Single stage room thermostat - Tecnoclima spa

Single stage room thermostat, with ON-OFF switch.

Double stage thermostat - Tecnoclima spa

Double stage thermostat with room temperature probe.

Double stage thermostat - Tecnoclima spa

Double stage thermostat with temperature probe for channel connection.

Double-stage/modulating electronic thermostat - Tecnoclima spa

Double-stage/modulating electronic thermostat (class VI) with LCD digital display complete with 3 position control signal.

Related products
  1. CMX

    Condensing suspended gas-fired room sealed heaters for duct systems with premix modulating gas burner

    THERMAL POWER
    from 23 to 1.090
    AIR FLOW
    from 4.600 to 71.000
  2. Condensing gas-fired warm air heaters for outside installation

    THERMAL POWER
    from 23 to 1.090
    AIR FLOW
    from 4.600 to 71.000
  3. Condensing vertical warm air heaters for inside installation

    THERMAL POWER
    from 23 to 1.090
    AIR FLOW
    from 4.600 to 71.000
  4. Condensing horizontal warm air heaters for outside installation

    THERMAL POWER
    from 23 to 1.090
    AIR FLOW
    from 4.600 to 71.000