Warm Air Heaters

SMX Condensing heating sections with premix modulating gas burner

for air handling units and roof top units
Type
Hot
Supply
Gas
Thermal
power
from 9,0
to 116,0
Air flow
from 3.200
to 13.000

Condensing heating sections SMX range with premix modulating gas burner are designed to be integrated into air treatment and roof-top units.
The modulating premix gas burner allows the continuous variation of the thermal power controllable through 0-10V signal. The premix technology ensures precise regulation with perfect mixing of the combustible gas with the combustion air and guarantees hygienic combustion with very low NOx emissions (Class 5). It is possible to combine several modules in series and in parallel to achieve high power and flow rates in very compact spaces. All sections are equipped with temperature probe and safety thermostat.
On request a ductable panelled version is available for indoor or outdoor installation, equipped with casing and flange for connection to the air ducts.

read more

Product informations

Description

Tecnoclima premix gas suspended warm air heaters have many advantages:

  • heat capacity of the premix burner has a wide modulation range: from 100 % to 30 % of the nominal heat capacity;
  • thanks to the modulation of the thermal capacity, as the demand for heat from the environment decreases, very high efficiency values are reached, up to 106%, with many benefi ts in terms of environmental comfort and the reduction of gas consumption;
  • the premix burner allows perfect mixing of the gas with the combustion air obtaining a semi-radiant fl ame band with very low emissions of nitrogen oxides, NOx: Class 5 of emissions;
  • very high thermal effi ciency and progressive modulation of the thermal power contribute to obtain operating cost savings of over 30 % compared to traditional systems.
Technical features

Description

U.M.

SMX 30

SMX 40

SMX 50

Max nominal heating capacity input (burned)

kW

29,1

38,5

49,8

kcal/h

25.057

33.111

42.822

Max USEFUL heating capacity output

kW

28,0

37,0

48,0

kcal/h

24.080

31.820

41.280

Min USEFUL heating capacity output

kW

10,0

14,0

19,0

kcal/h

8.600

12.040

16.340

Nominal air flow (*)

Nm3/h

3.200

4.400

5.500

 

Description

U.M.

SMX 60

SMX 90

SMX 120

Max nominal heating capacity input (burned)

kW

59,0

90,8

116,0

kcal/h

50.745

78.102

99.760

Max USEFUL heating capacity output

kW

57,0

89,0

115,0

kcal/h

49.020

76.540

98.900

Min USEFUL heating capacity output

kW

21,0

35,0

43,0

kcal/h

18.060

30.100

36.980

Nominal air flow (*)

Nm3/h

6.500

10.000

13.000

NOTES:
• The warm air heaters SMX are set to G20 natural gas. The conversion kit to natural gas G25 (where applicable) or propane gas G31 can be ordered separately (see accessories).
• Heating sections SMX require a power supply 230V50Hz 1N,an ON-OFF contact and a 0-10V signal for the power modulation.

Dimensions

Model

Dimensions mm

Chimney Ø mm

Weight kg

Weight (with package) kg

A

B

C

SMX

30

891

450

635

80

48

57

SMX

40

891

450

635

80

51

60

SMX

50

1234

450

685

80

62

72

SMX

60

1234

450

685

80

66

76

SMX

90

1755

450

840

100

122

133

SMX

120

1755

450

840

100

129

140

Supply description

CONDENSING HEATING SECTION consisting of:

  • Heat exchanger with combustion chamber made of AISI 430 stainless steel, with smoke pipes made of AISI 304 stainless steel with turbulence imprints, complete with inspection door, chimney connection and condensate discharge connection.
  • Containment panelling made of aluminized steel for definition of the air passage section.
  • Premix modulating burner with low CO and NOx emissions (Class 5), with wide regulation range, including semi-radiant flame tubular, modulating mixer and gas-air solenoid valve, DC brushless fan, ignition and ionisation electrodes for flame control.
  • Multifunctional electronic board for control and protection of the appliance by external 0-10V signal.
  • Multifunctional LED indicator to signal operating conditions or the presence of the main anomalies.
  • Safety temperature probe for overheating shutdown.
  • Flue exhaust connector complete with a sampling well for combustion products.
  • Siphon for the condensate discharge.

PACKAGE: Warm air heaters are packed in cardboard and pallet-loaded.

Applications
Related products
  1. PMX

    Condensing suspended gas-fired room sealed heaters for direct air diffusion with premix modulting gas burner

    THERMAL POWER
    from 9 to 116
    AIR FLOW
    from 3.200 to 13.000
  2. CMX

    Condensing suspended gas-fired room sealed heaters for duct systems with premix modulating gas burner

    THERMAL POWER
    from 9 to 116
    AIR FLOW
    from 3.200 to 13.000