Keypoints

  • Range consisting of 8 models
  • Heating capacity from 53 to 365 kW
  • Air flow rate from 4.800 to 33.000 m3/h
  • High efficiency up to ~ 103%
  • Versions available for indoor or outdoor installation
  • Suitable for both ducted systems and direct diffusion via diffusion plenum (accessory)
  • Versions available with increased static pressure for ducted diffusion systems
  • Possibility to combine with two-stage or modulating forced draught burners for the maximum efficiency
  • Gas fired
  • Compliant with ErP 2021 regulation and the regional requirements of Piedmont, Lombardy, Emilia Romagna, DM 26 June 2015
  • Versions available for tax deduction
read more

Warm Air Heaters

TC-EKO/K Condensing gas-fired warm air heaters for outside installation

Type
Hot
Supply
Gas
Thermal
power
from 20,0
to 365,0
Air flow
from 4.800
to 33.000

Product informations

Description

Outer casing composed of sandwich panels, with external surface in pre-painted galvanized steel, insulation in glass wool and internal surface in galvanized steel with anti-radiation effect.

Three-pass heat exchanger with combustion chamber in AISI 430 stainless steel and tube bundle composed of two rows of smoke pipes, of which the second in AISI 304 stainless steel; complete with exhaust manifold with condensate discharge, inspection doors, chimney connection and plate for burner application.

Fan assembly with one or more high performance, low sound level centrifugal fans, complete with electric motor(s) and variable belt transmission(s).

Electrical board for control and protection of the warm air heater designed for 400V 50Hz 3N power supply, complete with FAN, SAFETY (automatic reset) and LIMIT (manual reset).

Technical features

Description

U.M.

TC-EKO 60/K

TC-EKO 75/K

TC-EKO 100/K

TC-EKO 150/K

Max nominal heating capacity input (burned)

kW

53,8

64,1

97,7

130,0

kcal/h

46.270

55.130

84.030

111.800

Max USEFUL heating capacity output

kW

50,3

60,1

92,0

122,5

kcal/h

42.270

51.660

79.150

105.320

Nominal air flow

Nm3/h

4.800

6.300

8.300

10.900

Useful static pressure

Pa

220

220

220

220

 

Description

U.M.

TC-EKO 200/K

TC-EKO 250/K

TC-EKO 350/K

TC-EKO 450/K

Max nominal heating capacity input (burned)

kW

170,8

212,4

295,3

365,0

kcal/h

146.890

182.670

253.960

313.900

Max USEFUL heating capacity output

kW

161,4

200,9

280,8

347,1

kcal/h

138.810

172.810

241.520

298.520

Nominal air flow

Nm3/h

14.000

19.000

25.000

33.000

Useful static pressure

Pa

220

220

220

220

Dimensions

Model

Dimensions mm

Chimney Ø mm

Weight kg

Weight (with package) kg

A

B

C

D

TC-EKO 60/K

950

650

1770

600

150

333

338

TC-EKO 75/K

950

650

1770

600

150

338

343

TC-EKO 100/K

1200

800

2020

600

180

440

450

TC-EKO 150/K

1200

800

2020

600

180

465

475

TC-EKO 200/K

1500

1000

2270

800

200

685

695

TC-EKO 250/K

1500

1000

2270

800

200

705

715

TC-EKO 350/K

1800

1250

2470

1000

300

955

965

TC-EKO 450/K

1800

1250

2470

1000

300

1030

1040

Supply description

WARM AIR HEATER consisting of:

  • Three-pass heat exchanger with combustion chamber in AISI 430 stainless steel and tube bundle composed of two rows of smoke pipes, of which the second in AISI 304 stainless steel; complete with exhaust manifold with condensate discharge, inspection doors, chimney connection and plate for burner application.
  • Outer casing composed of sandwich panels, with external surface in pre-painted galvanized steel, insulation in glass wool and internal surface in galvanized steel with anti-radiation effect.
  • Side panel for air inlet section.
  • Fan assembly with one or more high performance, low sound level centrifugal fans, complete with electric motor(s) and variable belt transmission(s).
  • Electrical board for control and protection of the warm air heater designed for 400V 50Hz 3N power supply, complete with FANLIMIT thermostat (1 with automatic reset and 1 with manual reset).

PACKAGE: Warm air heaters are wrapped in plastic film and palletloaded.

Accessories

TC-EKO/K - Tecnoclima spa

  1. Side air filter

  2. Antirain inlet protection

Side air filter - Tecnoclima spa

1. Side air filter complete with metallic cabinet, with replaceable and regenerable filter elements, safety pressure switch for burner stopping when filter elements are obstructed.

Antirain inlet protection - Tecnoclima spa

2. Antirain inlet protection for air inlet mounting, complete with safety grid.

Air inlet regulation damper - Tecnoclima spa

Air inlet regulation damper made of galvanized steel, with opposed closing/opening blades and actuator pin.

Manual control - Tecnoclima spa

Manual control with different positions for air inlet damper.

Damper proportional actuator - Tecnoclima spa

Damper proportional actuator degree IP 54, for the damper regulation.

Single stage room thermostat - Tecnoclima spa

Single stage room thermostat, with ON-OFF switch.

Double stage thermostat - Tecnoclima spa

Double stage thermostat with room temperature probe.

Double stage thermostat - Tecnoclima spa

Double stage thermostat with temperature probe for channel connection.

Double stage/modulating electronic - Tecnoclima spa