Warm Air Heaters

PMX Condensing suspended gas-fired room sealed heaters

for direct air diffusion with premix modulting gas burner
Type
Hot
Supply
Gas
Thermal
power
from 6,0
to 116,0
Air flow
from 1.600
to 13.000

Condensing sealed warm air heaters with modulating premix gas burner, PMX range, are designed to be installed inside the environment and to diffuse the air directly into the environment to be heated. The PMX heaters has a diffuser panel with fins that are individually adjustable (vertically and orizontally) to direct the flow of warm air into the environment. The axial fans adopt motors with high energy efficiency and silent operation. The unit operates with variable thermal power with continuous modulation, fully automatically regulated from the remote control panel with integrated or remote environment temperature probe. The warm air heaters, thanks to the continuous modulation of the thermal capacity, decreases automatically the heating power, reaching performance values of up to 106%, consuming less fuel and ensuring ideal comfort and significant overall operating economy.
The PMX warm air heaters finds application in the heating of industrial and commercial environments, facilities for sports, entertainment, etc.

read more

Product informations

Description

Tecnoclima premix gas suspended warm air heaters have many advantages:

  • heat capacity of the premix burner has a wide modulation range: from 100 % to 30 % of the nominal heat capacity;
  • thanks to the modulation of the thermal capacity, as the demand for heat from the environment decreases, very high e ciency values are reached, up to 106%, with many benefits in terms of environmental comfort and the reduction of gas consumption;
  • the premix burner allows perfect mixing of the gas with the combustion air obtaining a semi-radiant flame band with very low emissions of nitrogen oxides, NOx: Class 5 of emissions;
  • very high thermal efficiency and progressive modulation of the thermal power contribute to obtain operating cost savings of over 30 % compared to traditional systems.
Technical features

 

Description

U.M.

PMX 15

PMX 30

PMX 40

Max nominal heating capacity input (burned)

kW

15,0

29,1

38,5

kcal/h

12.900

25.057

33.111

Max USEFUL heating capacity output

kW

14,4

28,0

37,0

kcal/h

12.380

24.080

31.820

Min USEFUL heating capacity output

kW

6,2

10,0

14,0

kcal/h

5.330

8.600

12.040

Nominal air flow

Nm3/h

1.600

3.200

4.4

NOTES:
The warm air heaters PMX are designed for indoor installation.
The warm air heaters PMX are set to G20 natural gas. The conversion kit to natural gas G25 (where applicable) or propane gas G31 can be ordered separately (see accessories).
The remote control panel is a mandatory accessory for correct operation of the heaters.

Description

U.M.

PMX 50

PMX 60

PMX 90

PMX 120

Max nominal heating capacity input (burned)

kW

49,8

59,0

90,8

116,0

kcal/h

42.822

50.745

78.102

99.760

Max USEFUL heating capacity output

kW

48,0

57,0

89,0

115,0

kcal/h

41.280

49.020

76.540

98.900

Min USEFUL heating capacity output

kW

19,0

21,0

35,0

43,0

kcal/h

16.340

18.060

30.100

36.980

Nominal air flow

Nm3/h

5.500

6.500

10.000

13.000

Dimensions


Model

Dimensions mm

Chimney Ø mm

Air connection Ø mm

Weight kg

Weight (with package) kg

A

B

C

PMX

15

885

830

580

80

80

60

71

PMX

30

885

830

580

80

80

65

77

PMX

40

885

830

580

80

80

75

88

PMX

50

1225

896

650

80

80

90

105

PMX

60

1225

896

650

80

80

95

110

PMX

90

1775

1081

800

100

100

205

225

PMX

120

1775

1081

800

100

100

215

237

Supply description

CONDENSING WARM AIR HEATER consisting of:

  • Heat exchanger with combustion chamber made of AISI 430 stainless steel, with smoke pipes made of AISI 304 stainless steel with turbulence imprints, complete with inspection door, chimney connection and condensate discharge connection.
  • External casing made of pre-painted or powder-coated galvanized steel, with thermal insulation.
  • Premix modulating burner with low CO and NOx emissions (Class 5), with wide regulation range, including semi-radiant flame tubular, modulating mixer and gas-air solenoid valve, DC brushless fan, ignition and ionisation electrodes for flame control.
  • Axial fan/s, single-phase 230V 50Hz 1N power supply for models PMX 15÷90 and three-phase 400V 50Hz 3N power supply for model PMX 120.
  • Multifunctional electronic board for control and protection of the warm air heater: ambient temperature control, burner start up, flame supervision and safety functions.
  • Multifunctional LED indicator to signal operating conditions or the presence of the main anomalies.
  • Safety temperature probe for overheating shutdown.
  • Air supply panel with individually adjustable vertical and horizontal fins to direct the warm air flow into the ambient.
  • Combustion air intake connection.
  • Flue exhaust connector complete with sampling well for combustion products.
  • Siphon for the condensate discharge.

PACKAGE: Warm air heaters are in cardboard and pallet-loaded.

Accessories
Remote control panel - Tecnoclima spa

Remote control panel complete with programmable thermostat and integrated ambient temperature probe, to manage the operating parameters, display diagnostic messages and reset the heater if necessary. Each remote control panel can manage up to 10 units.

Remote ambient air temperature probe - Tecnoclima Spa

Remote ambient air temperature probe.

Pair of support brackets - Tecnoclima spa

Pair of support brackets for wall anchoring.

Suspension kit - Tecnoclima spa

Suspension kit for ceiling installation of the unit.

Conversion kit to natural gas G25.

Conversion kit to natural gas G31.

Applications
Related products
  1. CMX

    Condensing suspended gas-fired room sealed heaters for duct systems with premix modulating gas burner

    THERMAL POWER
    from 6 to 116
    AIR FLOW
    from 1.600 to 13.000
  2. SMX

    Condensing heating sections with premix modulating gas burner for air handling units and roof top units

    THERMAL POWER
    from 6 to 116
    AIR FLOW
    from 1.600 to 13.000