Keypoints

  • Range consisting of 8 models
  • Heating capacity from 20 kW to 1.100 kW
  • Air flow rate from 4.600 to 71.000 m3/h
  • High efficiency up to ~ 103%
  • Versions available for indoor installation
  • Versions available for very low temperature installation
  • Suitable for both ducted systems and direct diffusion via diffusion plenum (accessory)
  • Versions available with increased static pressure for ducted diffusion systems
  • Possibility to combine with single-stage, two-stage or modulating forced draught burners for the maximum efficiency
  • Gas or oil fired
  • Available versions compliant with ErP 2021 regulation and the regional requirements of Piedmont, Lombardy, Emilia Romagna, DM 26 June 2015 and tax deduction
read more

Warm Air Heaters

ENERGY Condensing vertical warm air heaters for inside installation

Type
Hot
Supply
Gas
Oil
Thermal
power
from 23,0
to 1.090,0
Air flow
from 4.600
to 71.000

Tecnoclima cabinet warm air heaters ENERGY are the ideal solution for heating and controlled ventilation of medium large areas such as workshops, laboratories, industrial halls, warehouses, gyms, shopping centers, exhibition halls, theaters, churches, etc.

read more

Product informations

Description

External casing in pre-painted or powder-coated galvanized steel with insulation.

Heat exchanger three smokes rounds, with combustion chamber made of AISI 430 stainless steel, smoke pipes in AISI 304 stainless steel including turbolators, exhaust manifold with condensate discharge, inspection doors, chimney connection and burner mounting plate with insulation.

Fan section with one or more high performance centrifugal fans, complete with electric motor and variable belt transmission.

Electrical board for control and protection of the warm air heater designed for three phase electrical motor supply 400V 50Hz 3N, complete with FAN-LIMIT double thermostat (n°1 with manual reset and n°1 with automatic reset).

Technical features

Description

U.M.

ENERGY 60

ENERGY 105

ENERGY 160

ENERGY 220

Max nominal heating capacity input (burned)

kW

68,2

115,1

175,7

246,1

kcal/h

58.650

98.986

151.105

211.650

Max USEFUL heating capacity output

kW

60,1

103,5

160,3

217,1

kcal/h

51.686

89.010

137.858

186.706

Nominal air flow

Nm3/h

4.600

8.000

11.000

15.000

Useful static pressure

Pa

220

220

220

220

 

Description

U.M.

ENERGY 320

ENERGY 460

ENERGY 640

ENERGY 970

Max nominal heating capacity input (burned)

kW

349,8

502,9

715,2

1.089,8

kcal/h

300.830

432.495

615.045

937.230

Max USEFUL heating capacity output

kW

323,9

465,2

648,6

970,0

kcal/h

278.554

400.072

557.796

834.200

Nominal air flow

Nm3/h

21.500

31.000

43.000

71.000

Useful static pressure

Pa

220

220

220

220

Dimensions

Model

Dimensions mm

Chimney Ø mm

Weight kg

Weight (with package) kg

A

B

C

D

E

ENERGY 60

812

544

1.580

150

135

140

ENERGY 105

1.060

774

1.926

200

255

260

ENERGY 160

1.300

900

2.120

100

250

450

457

ENERGY 220

1.500

1.000

2.120

100

250

535

542

ENERGY 320

1.700

1.200

2.350

100

300

750

760

ENERGY 460

2.090

1.270

1.000

1.870

100

300

1.180

1.190

ENERGY 640

2.500

1.500

1.000

2.120

100

350

1.650

1.660

ENERGY 970

3.500

1.500

1.200

2.120

100

400

2.150

2.160

Supply description

CONDENSING WARM AIR HEATER consisting of:

  • Heat exchanger three smokes rounds, with combustion chamber made of AISI 430 stainless steel, smoke pipes in AISI 304 stainless steel including turbolators, exhaust manifold with condensate discharge, inspection doors, chimney connection and burner mounting plate with insulation.
  • External casing in pre-painted or powder-coated galvanized steel with insulation.
  • Side panel for air inlet section.
  • Side grid for air inlet section.
  • Fan section with one or more high performance centrifugal fans, complete with electric motor and variable belt transmission.
  • Electrical board for control and protection of the warm air heater designed for three phase electrical motor supply 400V 50Hz 3N, complete with FAN-LIMIT double thermostat (n° 1 with manual reset and n° 1 with automatic reset).

PACKAGE: Warm air heaters are wrapped in plastic film and palletloaded.

Accessories

ENERGY - Tecnoclima spa

  1. Side panel 

  2. Side grid

  3. Air filter

  4. Air diffusion plenum

  5. Air delivery grill

  6. Closing panel

Side panel - Tecnoclima spa

1. Side panel for air inlet section.

Side grid - Tecnoclima spa

2. Side grid for air inlet section.

Air filter - Tecnoclima spa

3. Air filter complete with metallic cabinet, with replaceable and regenerable filter elements, safety pressure switch for burner stopping when filter elements are obstructed (excluded for ENERGY 60 and ENERGY 105 models).

Air diffusion plenum - Tecnoclima spa

4. Air diffusion plenum complete with three or more air delivery grills and one or more closing panels depending on the model. The plenum is supplied disassembled, to be mounted on site by the customer.

Air delivery grill - Tecnoclima spa

5. Air delivery grill for plenum, with double row of vertical and horizontal adjustable fins to allow the air diffusion on the fourth side.

Closing panel - Tecnoclima spa

6. Closing panel or plenum in case of removal of one or more air delivery grills.

Regulation damper - Tecnoclima spa

Regulation damper made of galvanized steel, with opposed closing/opening blades and actuator pin. Power supply singlephase 230V 50Hz 1N.

Manual control - Tecnoclima spa

Manual control with different positions for air inlet damper.

Damper proportional actuator - Tecnoclima spa

Damper proportional actuator degree IP 54, for the damper regulation.

Remote control - Tecnoclima spa

Remote control for the remote damper command with 0 ÷ 10V output.

Single stage room thermostat - Tecnoclima spa

Single stage room thermostat, with ON-OFF switch.

Double stage thermostat - Tecnoclima spa

Double stage thermostat with room temperature probe.

Double stage thermostat - Tecnoclima spa

Double stage thermostat with temperature probe for channel connection.

Double-stage/modulating electronic thermostat - Tecnoclima spa

Double-stage/modulating electronic thermostat (class VI) with LCD digital display complete with 3 position control signal.

Control system

The Tecnoclima cabinet warm air heaters ENERGY series can be equipped with a room chronothermostat for simple and intuitive management.
The device works with any type of burner, single-stage / two-stage / modulating and displays the main values regarding the operating of the air heater.
Normally the display shows the room temperature, time and operating status of the air heater.

The panel can be used to access other functions such as:
• Changing the set-point of the required room temperature.
• Display of additional sensors on board the machine.
• Display and reset of the alarms.
• When required, setting of the operating time periods.
• Variation of some operating parameters.

ENERGY controllo Tecnoclima

Related products
  1. PMX

    Condensing suspended gas-fired room sealed heaters for direct air diffusion with premix modulting gas burner

    THERMAL POWER
    from 23 to 1.090
    AIR FLOW
    from 4.600 to 71.000
  2. Very high-efficiency istantaneous condensing warm air heaters with modulating burner

    THERMAL POWER
    from 23 to 1.090
    AIR FLOW
    from 4.600 to 71.000
  3. Condensing horizontal warm air heaters for inside installation

    THERMAL POWER
    from 23 to 1.090
    AIR FLOW
    from 4.600 to 71.000
  4. Condensing vertical warm air heaters for outside installation

    THERMAL POWER
    from 23 to 1.090
    AIR FLOW
    from 4.600 to 71.000